9VCK
Cryo-EM structure of SARS-CoV-2 nsp10/nsp14:RNA:SMP complex
EM specimen
Vitrification | Yes |
EM Data Collection
Microscope | TFS KRIOS |
Electron Gun | FIELD EMISSION GUN |
Accelerating Voltage (kV) | 300 |
Detector | GATAN K3 BIOQUANTUM (6k x 4k) |
3D Reconstruction
Method | SINGLE PARTICLE |
Resolution (Å) | 4.22 |
Software | cryoSPARC,PHENIX |
CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |