Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 80 |
| Detector technology | CCD |
| Collection date | 2023-10-30 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.97918 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 66.940, 77.350, 115.310 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 57.660 - 2.200 |
| R-factor | 0.2637 |
| Rwork | 0.260 |
| R-free | 0.31230 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.709 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.19.2_4158: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 57.660 | 2.279 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Rmerge | 0.380 | |
| Number of reflections | 31042 | 3054 |
| <I/σ(I)> | 6.17 | 1.49 |
| Completeness [%] | 99.4 | 99.09 |
| Redundancy | 12.8 | 13.2 |
| CC(1/2) | 0.996 | 0.808 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 16% PEG 3350, 100 mM (NH4)2SO4, 100 mM HEPES, pH 7.5 |