9TDA
ERAP1 in complex with 1-[2-(5-bromo-7-fluoro-2-oxo-2,3-dihydro-1,3-benzothiazol-3-yl)acetamido]-4,4-difluorocyclohexane-1-carboxylic acid
This is a non-PDB format compatible entry.
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-07-02 |
| Detector | DECTRIS EIGER2 S 16M |
| Wavelength(s) | 0.9537 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 112.809, 140.226, 57.742 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 87.900 - 1.550 |
| R-factor | 0.1685 |
| Rwork | 0.167 |
| R-free | 0.20020 |
| Structure solution method | FOURIER SYNTHESIS |
| RMSD bond length | 0.010 |
| RMSD bond angle | 0.970 |
| Data reduction software | autoPROC |
| Data scaling software | STARANISO |
| Phasing software | BUSTER |
| Refinement software | BUSTER (2.11.8 (10-JUL-2024)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 88.000 | 1.680 |
| High resolution limit [Å] | 1.550 | 1.550 |
| Rmeas | 0.154 | |
| Number of reflections | 101757 | 5088 |
| <I/σ(I)> | 10.6 | |
| Completeness [%] | 76.4 | |
| Redundancy | 13.7 | |
| CC(1/2) | 0.683 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 5% w/v PEG 1500, 0.1 M SPG buffer pH 4.8 |