9PZB
HCMV trimer in complex with E4K, E11K, A9K, E9L, E8K, B1K, E7K, F12L and E10L Fabs
EM specimen
| Vitrification | Yes |
EM Data Collection
| Microscope | TFS GLACIOS |
| Electron Gun | FIELD EMISSION GUN |
| Accelerating Voltage (kV) | 200 |
| Detector | FEI FALCON IV (4k x 4k) |
3D Reconstruction
| Method | SINGLE PARTICLE |
| Resolution (Å) | 3.2 |
| Software | cryoSPARC,PHENIX |
| CTF correction | NONE |