Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PETRA III, DESY BEAMLINE P11 |
| Synchrotron site | PETRA III, DESY |
| Beamline | P11 |
| Temperature [K] | 90 |
| Detector technology | PIXEL |
| Collection date | 2022-08-25 |
| Detector | DECTRIS EIGER2 X 16M |
| Wavelength(s) | 1.03321 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 46.160, 70.180, 78.710 |
| Unit cell angles | 90.00, 90.01, 90.00 |
Refinement procedure
| Resolution | 46.200 - 1.860 |
| R-factor | 0.17734 |
| Rwork | 0.175 |
| R-free | 0.21758 |
| Structure solution method | FOURIER SYNTHESIS |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.531 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | REFMAC |
| Refinement software | REFMAC (5.8.0430) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 46.200 | 1.910 |
| High resolution limit [Å] | 1.860 | 1.870 |
| Rmerge | 0.300 | 0.910 |
| Rmeas | 0.325 | 1.002 |
| Rpim | 0.123 | 0.412 |
| Total number of observations | 13878 | |
| Number of reflections | 41050 | 2493 |
| <I/σ(I)> | 8.9 | 3.1 |
| Completeness [%] | 98.7 | |
| Redundancy | 6.8 | 5.6 |
| CC(1/2) | 0.992 | 0.839 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | 0.2 M Magnesium chloride 0.1 M TRIS pH 8.5 33 % w/v PEG 4000 |