9I24
Coagulation factor Xa complex with a2-loop peptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-07-05 |
| Detector | DECTRIS EIGER2 XE 16M |
| Wavelength(s) | 0.70979 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 48.473, 72.419, 82.335 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 54.378 - 1.200 |
| Rwork | 0.141 |
| R-free | 0.17180 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.977 |
| Data reduction software | DIALS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0425) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 54.380 | 1.220 |
| High resolution limit [Å] | 1.200 | 1.200 |
| Rmerge | 0.069 | |
| Rpim | 0.633 | |
| Number of reflections | 89301 | 4305 |
| <I/σ(I)> | 14.3 | 1.3 |
| Completeness [%] | 98.1 | 96.5 |
| Redundancy | 13.7 | 14.4 |
| CC(1/2) | 0.998 | 0.672 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 287 | imidazole, MPD |