Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-07-24 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.97998 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 37.065, 41.054, 209.005 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 104.500 - 1.820 |
R-factor | 0.2358 |
Rwork | 0.234 |
R-free | 0.26810 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.020 |
RMSD bond angle | 2.083 |
Data reduction software | XDS |
Data scaling software | Aimless |
Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 209.005 | 209.005 | 1.849 |
High resolution limit [Å] | 1.818 | 4.934 | 1.818 |
Rmerge | 0.144 | 0.051 | 0.913 |
Rmeas | 0.166 | 0.059 | 1.001 |
Rpim | 0.088 | 0.031 | 0.529 |
Number of reflections | 29802 | 1653 | 1501 |
<I/σ(I)> | 10.5 | ||
Completeness [%] | 99.9 | 99.5 | 99.9 |
Redundancy | 6.3 | 5.8 | 6.5 |
CC(1/2) | 0.997 | 0.998 | 0.737 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.9 | 292 | 25% PEG 8000, 300 mM LiCl, 100 mM bis-tris propane |