Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-03-18 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.0 |
Spacegroup name | F 2 3 |
Unit cell lengths | 177.590, 177.590, 177.590 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 25.000 - 2.500 |
R-factor | 0.202 |
Rwork | 0.201 |
R-free | 0.22000 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.060 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.7) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 25.000 | 10.000 | 2.570 |
High resolution limit [Å] | 2.500 | 10.000 | 2.500 |
Rmerge | 0.193 | 0.050 | 1.800 |
Rmeas | 0.198 | 0.052 | 1.000 |
Number of reflections | 16143 | 193 | 1178 |
<I/σ(I)> | 14.41 | ||
Completeness [%] | 99.9 | ||
Redundancy | 20 | ||
CC(1/2) | 0.999 | 0.999 | 0.694 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 294 | 10 % PEG8000, LITHIUM SULPHATE 0.5M |