Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-06-16 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.00 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 54.534, 98.971, 58.825 |
Unit cell angles | 90.00, 106.60, 90.00 |
Refinement procedure
Resolution | 35.930 - 2.200 |
R-factor | 0.2044 |
Rwork | 0.203 |
R-free | 0.23520 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.004 |
RMSD bond angle | 0.602 |
Data reduction software | autoPROC |
Data scaling software | autoPROC |
Phasing software | PHENIX |
Refinement software | PHENIX (1.21.1_5286) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 35.930 | 2.279 |
High resolution limit [Å] | 2.200 | 2.200 |
Number of reflections | 30464 | 3025 |
<I/σ(I)> | 9.69 | |
Completeness [%] | 99.7 | 99.74 |
Redundancy | 3.5 | |
CC(1/2) | 0.995 | 0.839 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 296 | 20% PEG 6000, 0.1M MES pH 6.0, 0.2M NaCl |