9DRW

Myocilin OLF mutant A427T

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS-II BEAMLINE 19-ID
Synchrotron siteNSLS-II
Beamline19-ID
Temperature [K]80
Detector technologyPIXEL
Collection date2023-11-02
DetectorDECTRIS EIGER2 X 9M
Wavelength(s)1.00
Spacegroup nameC 1 2 1
Unit cell lengths140.930, 47.810, 149.990
Unit cell angles90.00, 107.71, 90.00
Refinement procedure
Resolution58.620 - 1.450
R-factor0.1462
Rwork0.146
R-free0.18820
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle0.806
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]58.6201.502
High resolution limit [Å]1.4501.450
Rmerge0.0640.538
Rmeas0.0700.593
Rpim0.0270.241
Number of reflections16085012829
<I/σ(I)>16.184.45
Completeness [%]95.176.52
Redundancy6.75.7
CC(1/2)0.9990.912
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.228910% PEG8000, 0.05M magnesium chloride