9DP4
APE1 N174Q Product Complex with Abasic DNA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-02-12 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.54 |
Spacegroup name | P 43 |
Unit cell lengths | 153.423, 153.423, 45.373 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.520 - 2.250 |
R-factor | 0.2208 |
Rwork | 0.215 |
R-free | 0.24850 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.013 |
RMSD bond angle | 1.816 |
Data reduction software | HKL-3000 (705c) |
Data scaling software | HKL-3000 (705c) |
Phasing software | PHENIX (1.19.2-4158-000) |
Refinement software | PHENIX ((1.19.2_4158: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.520 | 2.290 |
High resolution limit [Å] | 2.250 | 2.250 |
Rmeas | 0.100 | |
Number of reflections | 63992 | 2206 |
<I/σ(I)> | 13.74 | 0.84 |
Completeness [%] | 98.5 | 86.7 |
Redundancy | 5.6 | 2.4 |
CC(1/2) | 0.616 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 295 | 100 mM HEPES free acid, 200 mM ammonium acetate, 25% PEG3350 |