Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-06-09 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 90.813, 90.813, 122.738 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 78.650 - 1.490 |
R-factor | 0.12703 |
Rwork | 0.126 |
R-free | 0.15573 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.018 |
RMSD bond angle | 1.855 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 78.650 | 1.740 |
High resolution limit [Å] | 1.490 | 1.490 |
Number of reflections | 95535 | 35297 |
<I/σ(I)> | 13.75 | 3.01 |
Completeness [%] | 99.6 | 99.9 |
Redundancy | 3.5 | 3.5 |
CC(1/2) | 0.999 | 0.831 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | 0.10 M NaAcetate pH4.8, 2.0 M (NH4)2SO4 30 % Glycerol |