Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-D |
| Synchrotron site | APS |
| Beamline | 21-ID-D |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-10-06 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.1271 |
| Spacegroup name | P 31 |
| Unit cell lengths | 60.860, 60.860, 89.050 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 30.430 - 1.684 |
| R-factor | 0.1782 |
| Rwork | 0.177 |
| R-free | 0.20370 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 0.940 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | BUSTER (2.10.4 (23-JAN-2024)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 1.710 |
| High resolution limit [Å] | 1.680 | 4.560 | 1.680 |
| Rmerge | 0.099 | 0.045 | 0.685 |
| Rmeas | 0.105 | 0.048 | 0.743 |
| Rpim | 0.034 | 0.014 | 0.284 |
| Total number of observations | 381153 | ||
| Number of reflections | 41720 | 2090 | 2101 |
| <I/σ(I)> | 9.5 | ||
| Completeness [%] | 99.9 | 99.6 | 99.5 |
| Redundancy | 9.1 | 10.8 | 6.7 |
| CC(1/2) | 0.998 | 0.998 | 0.908 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 32% Peg 3350, 50mM ZnAc, 6% Sucrose |