Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9C4Y

Menin mutant - T349M

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-G
Synchrotron siteAPS
Beamline21-ID-G
Temperature [K]100
Detector technologyCCD
Collection date2023-04-08
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.97857
Spacegroup nameP 21 21 21
Unit cell lengths49.024, 80.268, 124.941
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution28.916 - 1.309
Rwork0.162
R-free0.18290
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.013
RMSD bond angle2.024
Data reduction softwareHKL-2000 (722)
Data scaling softwareHKL-2000 (722)
Phasing softwareMOLREP (11.0 / 22.07.2010/)
Refinement softwareREFMAC (5.8.0425)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.330
High resolution limit [Å]1.3091.309
Rmerge0.0980.707
Number of reflections1189015800
<I/σ(I)>30.02
Completeness [%]99.898.3
Redundancy7.26.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2850.2 M lithium sulfate, 0.1 M HEPES, pH 7.5, 25% (w/v) PEG-3,350

237735