Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9T07

HUMAN PI3KDELTA IN COMPLEX WITH Roginolisib

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2011-02-07
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9999
Spacegroup nameP 21 21 21
Unit cell lengths93.032, 113.387, 144.506
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.520 - 2.750
R-factor0.2318
Rwork0.231
R-free0.27250
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)NONE
RMSD bond length0.007
RMSD bond angle0.850
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.8 (17-JUL-2025))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]89.2003.000
High resolution limit [Å]2.7502.750
Rmeas0.0400.493
Number of reflections391348981
<I/σ(I)>24.063.23
Completeness [%]96.797.9
Redundancy4.84.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION29316% PEG6000, 0.10 M KCL, 0.10 M MES pH 6.0

256789

PDB entries from 2026-07-22