Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | Cu FINE FOCUS |
| Temperature [K] | 80 |
| Detector technology | IMAGE PLATE |
| Collection date | 2022-04-21 |
| Detector | RIGAKU |
| Wavelength(s) | 1.5870 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 42.280, 61.543, 59.987 |
| Unit cell angles | 90.00, 97.73, 90.00 |
Refinement procedure
| Resolution | 42.755 - 2.068 |
| R-factor | 0.1679 |
| Rwork | 0.166 |
| R-free | 0.20530 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.734 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 42.760 | 2.141 |
| High resolution limit [Å] | 2.068 | 2.068 |
| Rmerge | 0.189 | 0.329 |
| Rmeas | 0.203 | |
| Number of reflections | 18740 | 1832 |
| <I/σ(I)> | 9.46 | 4.79 |
| Completeness [%] | 99.8 | 98.07 |
| Redundancy | 7.2 | 5.7 |
| CC(1/2) | 0.987 | 0.913 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.1 M Bis-Tris (pH 4.5), 0.2 M Li2SO4, and 19% PEG3350 |