8Z95
Humanized anti-PEG h6.3 Fab in complex with PEG
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSRRC BEAMLINE BL13B1 |
| Synchrotron site | NSRRC |
| Beamline | BL13B1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2020-04-02 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 245.365, 43.574, 110.148 |
| Unit cell angles | 90.00, 111.70, 90.00 |
Refinement procedure
| Resolution | 29.810 - 2.260 |
| R-factor | 0.21214 |
| Rwork | 0.209 |
| R-free | 0.26148 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6vl9 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.494 |
| Data scaling software | SCALA |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0411) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 30.000 | 30.000 | 2.350 |
| High resolution limit [Å] | 2.260 | 4.880 | 2.270 |
| Rmerge | 0.018 | 0.333 | |
| Rmeas | 0.053 | 0.022 | 0.391 |
| Rpim | 0.012 | 0.202 | |
| Number of reflections | 50690 | 5209 | 4989 |
| <I/σ(I)> | 14.3 | ||
| Completeness [%] | 99.1 | 97.9 | 99.2 |
| Redundancy | 3.6 | 3.3 | 3.7 |
| CC(1/2) | 0.999 | 0.900 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 18% (w/v) PEG-6000, 1% (w/v) PEG-2000-methyl ether, 0.15 M lithium sulfate monohydrate, and 0.1 M citric acid |