8Z6U
SARS-CoV-2 EG.5.1 Spike in complex with CYFN1006-2(S-CYFN1006-2 dimer trimer).
EM specimen
| Vitrification | Yes |
EM Data Collection
| Microscope | FEI TITAN KRIOS |
| Electron Gun | FIELD EMISSION GUN |
| Accelerating Voltage (kV) | 300 |
| Detector | FEI FALCON IV (4k x 4k) |
3D Reconstruction
| Method | SINGLE PARTICLE |
| Resolution (Å) | 3.83 |
| CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |