8WKG
Rational Design of Highly Selective PDE5 inhibitors for the Treatment of Idiopathic Pulmonary Fibrosis
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-06-08 |
Detector | RIGAKU HyPix-3000 |
Wavelength(s) | 1.54056 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 74.090, 74.090, 131.084 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 24.270 - 2.400 |
Rwork | 0.186 |
R-free | 0.23520 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | CrysalisPro |
Data scaling software | CrysalisPro |
Phasing software | PHASER |
Refinement software | PHENIX ((1.16_3549: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 24.270 | 2.490 |
High resolution limit [Å] | 2.400 | 2.400 |
Number of reflections | 16888 | 1734 |
<I/σ(I)> | 21.4 | |
Completeness [%] | 99.9 | 100 |
Redundancy | 9 | |
CC(1/2) | 0.999 | 0.799 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 0.2 M magnesium sulfate, 0.1 M sodium cacodylate, pH 6.5, 17% PEG3350 |