8W92
human H ferritin with 2 Fe(II)/subunit loading
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL02U1 |
Synchrotron site | SSRF |
Beamline | BL02U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-06-01 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1.6314 |
Spacegroup name | F 4 3 2 |
Unit cell lengths | 182.220, 182.220, 182.220 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 37.200 - 2.120 |
R-factor | 0.1667 |
Rwork | 0.165 |
R-free | 0.20030 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.820 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 37.200 | 2.196 |
High resolution limit [Å] | 2.120 | 2.121 |
Number of reflections | 15266 | 1491 |
<I/σ(I)> | 31.86 | |
Completeness [%] | 99.9 | |
Redundancy | 28 | |
CC(1/2) | 1.000 | 0.832 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM HEPES, pH7, 20 mM CaCl2 |