8ULK
Prefusion RSV F bound by neutralizing antibody 1G12
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-03-13 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 143.982, 174.605, 226.286 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.950 - 4.280 |
R-factor | 0.246 |
Rwork | 0.244 |
R-free | 0.27860 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond angle | 5.079 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.950 | 4.430 |
High resolution limit [Å] | 4.280 | 4.280 |
Number of reflections | 36919 | 1605 |
<I/σ(I)> | 7.2 | |
Completeness [%] | 72.9 | |
Redundancy | 7.3 | |
CC(1/2) | 0.940 | 0.640 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 0.2 M Sodium sulfate, 20 % w/v PEG 3350 |