Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8TUU

MW Polyomavirus LTA bipartite NLS bound to importin alpha 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX1
Synchrotron siteAustralian Synchrotron
BeamlineMX1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-06-09
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.9537
Spacegroup nameP 21 21 21
Unit cell lengths77.390, 90.067, 100.146
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.350 - 2.500
R-factor0.2037
Rwork0.202
R-free0.23530
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.002
RMSD bond angle0.513
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.3502.600
High resolution limit [Å]2.5002.500
Rmerge0.1201.090
Rmeas0.1301.180
Rpim0.0500.450
Number of reflections248582728
<I/σ(I)>11.92
Completeness [%]99.9
Redundancy6.7
CC(1/2)1.0000.700
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2960.7 M sodium citrate, 0.1 M HEPES pH 7.5, 0.01 M DTT

224931

PDB entries from 2024-09-11

PDB statisticsPDBj update infoContact PDBjnumon