Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8TO4

EGFR(T790M/V948R) in complex with the allosteric inhibitor FRF-06-057

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS-II BEAMLINE 17-ID-2
Synchrotron siteNSLS-II
Beamline17-ID-2
Temperature [K]100
Detector technologyPIXEL
Collection date2021-08-05
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.97933
Spacegroup nameP 1 21 1
Unit cell lengths72.346, 103.109, 86.867
Unit cell angles90.00, 101.24, 90.00
Refinement procedure
Resolution70.960 - 2.990
R-factor0.1759
Rwork0.171
R-free0.23100
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.019
RMSD bond angle1.425
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.19_4092)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]70.9603.180
High resolution limit [Å]2.9903.000
Rmerge0.2030.670
Rmeas0.2430.806
Rpim0.1320.443
Total number of observations12858
Number of reflections252324006
<I/σ(I)>4.61.9
Completeness [%]99.8
Redundancy3.33.2
CC(1/2)0.9250.548
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.529825% PEG-3350, Bis-Tris 0.1 M

224201

PDB entries from 2024-08-28

PDB statisticsPDBj update infoContact PDBjnumon