8TAB
RTA-PD00589
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-E |
| Synchrotron site | APS |
| Beamline | 24-ID-E |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-03-10 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 63 2 2 |
| Unit cell lengths | 169.146, 169.146, 55.913 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 48.830 - 2.260 |
| R-factor | 0.1874 |
| Rwork | 0.186 |
| R-free | 0.21870 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.609 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 2.290 |
| High resolution limit [Å] | 2.250 | 6.100 | 2.250 |
| Rmerge | 0.200 | 0.077 | 1.422 |
| Rmeas | 0.080 | 1.518 | |
| Rpim | 0.022 | 0.515 | |
| Number of reflections | 22196 | 1252 | 1030 |
| <I/σ(I)> | 4.3 | ||
| Completeness [%] | 99.2 | 99.6 | 92.6 |
| Redundancy | 10.3 | 12.5 | 7.9 |
| CC(1/2) | 0.997 | 0.614 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 295 | 200 mM Mg(NO3)2 and 20% PEG 3350 |