8SE6
NKG2D complexed with inhibitor 36
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-02-23 |
Detector | DECTRIS EIGER2 X 9M |
Wavelength(s) | 1.0 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 100.041, 43.483, 64.188 |
Unit cell angles | 90.00, 102.87, 90.00 |
Refinement procedure
Resolution | 43.440 - 1.360 |
R-factor | 0.1948 |
Rwork | 0.194 |
R-free | 0.21080 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.910 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 62.580 | 1.380 |
High resolution limit [Å] | 1.360 | 1.360 |
Rmerge | 0.050 | 0.778 |
Rmeas | 0.059 | 0.972 |
Rpim | 0.032 | 0.573 |
Total number of observations | 172740 | 3361 |
Number of reflections | 52859 | 1395 |
<I/σ(I)> | 9.9 | 1 |
Completeness [%] | 91.1 | |
Redundancy | 3.3 | 2.4 |
CC(1/2) | 0.999 | 0.713 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.15 - 0.22 M NaNO3, 20- 31 % (w/v) PEG 3350 |