8RUZ
Anaerobic HIF prolyl-hydroxylase-2 (PHD2) T387S variant bound to acetate (ACT) and Hypoxia-inducible Factor-2alpha (HIF-2alpha)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-01-24 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9762 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 130.295, 37.951, 42.076 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.080 - 1.820 |
R-factor | 0.2658 |
Rwork | 0.263 |
R-free | 0.31440 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.535 |
Data reduction software | autoPROC |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.080 | 1.850 |
High resolution limit [Å] | 1.820 | 1.820 |
Number of reflections | 19502 | 935 |
<I/σ(I)> | 7.8 | |
Completeness [%] | 100.0 | |
Redundancy | 12.9 | |
CC(1/2) | 1.000 | 0.400 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 297 | (10-35%) PEG 4K, 0.2 M ammonium acetate and 0.1 M sodium ammonium acetate trihydrate pH (4.1-5.6). |