8P7C
CryoEM structure of METTL6 tRNA SerRS complex in a 2:2:2 stoichiometry
EM specimen
Vitrification | Yes |
EM Data Collection
Microscope | FEI TITAN KRIOS |
Electron Gun | FIELD EMISSION GUN |
Accelerating Voltage (kV) | 300 |
Detector | GATAN K3 BIOQUANTUM (6k x 4k) |
3D Reconstruction
Method | SINGLE PARTICLE |
Resolution (Å) | 3.7 |
Symmetry | C2 |
CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |