8P29
TEAD2 in complex with an inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE MASSIF-1 |
Synchrotron site | ESRF |
Beamline | MASSIF-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-07-04 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.966 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 121.842, 61.652, 80.018 |
Unit cell angles | 90.00, 117.51, 90.00 |
Refinement procedure
Resolution | 57.720 - 2.060 |
R-factor | 0.1978 |
Rwork | 0.195 |
R-free | 0.24010 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 0.931 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 57.720 | 2.130 |
High resolution limit [Å] | 2.060 | 2.060 |
Number of reflections | 58253 | 3205 |
<I/σ(I)> | 9.63 | |
Completeness [%] | 98.8 | |
Redundancy | 1.8 | |
CC(1/2) | 0.998 | 0.931 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 2.8M sodium formate |