8GHO
GUCY2C-peptide bound to anti-GUCY2C-scFv antibody
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2018-09-21 |
Detector | DECTRIS PILATUS 300K |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 70.680, 80.570, 90.700 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 31.960 - 1.600 |
R-factor | 0.198 |
Rwork | 0.197 |
R-free | 0.21700 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.090 |
Data reduction software | autoPROC |
Data scaling software | STARANISO |
Phasing software | PHASER |
Refinement software | BUSTER |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 60.000 | 1.770 |
High resolution limit [Å] | 1.600 | 1.600 |
Rmerge | 0.085 | 0.900 |
Number of reflections | 49431 | 2472 |
<I/σ(I)> | 12.3 | |
Completeness [%] | 92.9 | 61.7 |
Redundancy | 6.6 | 6.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 20% PEG 3350, 200 mM Lithium Sulfate, bis-tris pH 5.5 |