8FZK
Dimeric human importin alpha subunit
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-10-12 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.9537 |
Spacegroup name | P 1 |
Unit cell lengths | 50.107, 90.838, 94.603 |
Unit cell angles | 103.19, 90.37, 97.39 |
Refinement procedure
Resolution | 29.910 - 2.100 |
R-factor | 0.2036 |
Rwork | 0.201 |
R-free | 0.24680 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.016 |
RMSD bond angle | 1.387 |
Data reduction software | DIALS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 29.910 | 2.175 |
High resolution limit [Å] | 2.100 | 2.100 |
Rmerge | 0.068 | 0.527 |
Rpim | 0.042 | |
Number of reflections | 92088 | 8992 |
<I/σ(I)> | 21.41 | 1.16 |
Completeness [%] | 98.0 | |
Redundancy | 3.5 | |
CC(1/2) | 0.997 | 0.757 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 14% PEG 8000, 0.2M Magnesium chloride, 0.1M MES |