Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-10-03 |
Detector | DECTRIS EIGER R 1M |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 63.474, 70.730, 148.190 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.205 - 2.852 |
R-factor | 0.1996 |
Rwork | 0.198 |
R-free | 0.23840 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 1.579 |
Data reduction software | HKL-2000 |
Data scaling software | Aimless |
Phasing software | FFT |
Refinement software | PHENIX (1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 74.095 | 2.862 |
High resolution limit [Å] | 2.852 | 2.852 |
Rmerge | 0.150 | 0.795 |
Number of reflections | 16191 | 156 |
<I/σ(I)> | 12.4 | |
Completeness [%] | 100.0 | |
Redundancy | 6.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 20.0% Peg-6000, 0.1M Tris pH8.0 |