Cryo-EM structure of the SARS-CoV-2 Omicron HR1-42G complex

EM specimen
VitrificationYes
EM Data Collection
MicroscopeFEI TITAN KRIOS
Electron GunFIELD EMISSION GUN
Accelerating Voltage (kV)300
DetectorGATAN K3 (6k x 4k)
3D Reconstruction
MethodSINGLE PARTICLE
Resolution (Å)2.82
CTF correctionNONE