8C6I
TMEM2 ectodomain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-02-03 |
Detector | DECTRIS EIGER2 S 16M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 42 21 2 |
Unit cell lengths | 184.760, 184.760, 105.398 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 91.550 - 3.500 |
R-factor | 0.2678 |
Rwork | 0.265 |
R-free | 0.31890 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.004 |
RMSD bond angle | 0.638 |
Data reduction software | DIALS |
Data scaling software | DIALS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.18) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 92.350 | 3.560 |
High resolution limit [Å] | 3.500 | 3.500 |
Rpim | 0.073 | 0.871 |
Number of reflections | 23570 | 1159 |
<I/σ(I)> | 7.1 | 0.5 |
Completeness [%] | 100.0 | |
Redundancy | 26.8 | |
CC(1/2) | 0.997 | 0.424 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.5 | 293 | 0.1 M sodium acetate, pH 4.5, 30% polyethyleneglycol 3000 |