8AZV
KRAS in complex with BI-2865
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-05-18 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.000004 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 86.470, 40.632, 56.170 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.260 - 1.050 |
R-factor | 0.1556 |
Rwork | 0.155 |
R-free | 0.17350 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 8afb |
RMSD bond length | 0.009 |
RMSD bond angle | 1.116 |
Data reduction software | XDS |
Data scaling software | STARANISO |
Phasing software | PHASER |
Refinement software | PHENIX (1.20_4459) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.104 | 1.122 |
High resolution limit [Å] | 1.047 | 1.047 |
Rmerge | 0.052 | 0.886 |
Number of reflections | 77612 | 3882 |
<I/σ(I)> | 20 | 1.6 |
Completeness [%] | 82.6 | 22.2 |
Redundancy | 12.1 | 7.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.2mM Magnesium Chloride, 20% PEG 2000, 100mM sodium acetate pH 4.4 |