Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8AIQ

Mpro of SARS COV-2 in complex with the MG-87 inhibitor

This is a non-PDB format compatible entry.
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, DESY BEAMLINE P11
Synchrotron sitePETRA III, DESY
BeamlineP11
Temperature [K]100
Detector technologyPIXEL
Collection date2021-11-24
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0332
Spacegroup nameP 1 21 1
Unit cell lengths45.941, 63.773, 103.513
Unit cell angles90.00, 91.25, 90.00
Refinement procedure
Resolution45.972 - 2.190
Rwork0.168
R-free0.22290
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6y2e
RMSD bond length0.009
RMSD bond angle1.579
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.9722.260
High resolution limit [Å]2.1902.190
Rmerge0.133
Number of reflections305432906
<I/σ(I)>10.9
Completeness [%]98.6
Redundancy6.9
CC(1/2)0.9960.852
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52930.02 M sodium/potassium phosphate, 0.1 M Bis Tris propane pH8.5, 20 % w/v PEG 3350

227344

PDB entries from 2024-11-13