8W92
human H ferritin with 2 Fe(II)/subunit loading
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-06-01 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.6314 |
| Spacegroup name | F 4 3 2 |
| Unit cell lengths | 182.220, 182.220, 182.220 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 37.200 - 2.120 |
| R-factor | 0.1667 |
| Rwork | 0.165 |
| R-free | 0.20030 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.820 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 37.200 | 2.196 |
| High resolution limit [Å] | 2.120 | 2.121 |
| Number of reflections | 15266 | 1491 |
| <I/σ(I)> | 31.86 | |
| Completeness [%] | 99.9 | |
| Redundancy | 28 | |
| CC(1/2) | 1.000 | 0.832 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM HEPES, pH7, 20 mM CaCl2 |