8VQ8

Immune receptor complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2022-10-25
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.95373
Spacegroup nameH 3
Unit cell lengths197.604, 197.604, 79.331
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution49.400 - 2.010
R-factor0.1881
Rwork0.187
R-free0.21510
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.836
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.4002.050
High resolution limit [Å]2.0102.010
Rmerge0.1161.296
Rmeas0.124
Rpim0.0430.454
Number of reflections769944527
<I/σ(I)>111.5
Completeness [%]99.998.5
Redundancy8.18
CC(1/2)0.9950.609
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.2293.150.1 M SPG pH 8.2, 5.0 %w/v PEG 1500