8VQ8
Immune receptor complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-10-25 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.95373 |
Spacegroup name | H 3 |
Unit cell lengths | 197.604, 197.604, 79.331 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 49.400 - 2.010 |
R-factor | 0.1881 |
Rwork | 0.187 |
R-free | 0.21510 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.836 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.400 | 2.050 |
High resolution limit [Å] | 2.010 | 2.010 |
Rmerge | 0.116 | 1.296 |
Rmeas | 0.124 | |
Rpim | 0.043 | 0.454 |
Number of reflections | 76994 | 4527 |
<I/σ(I)> | 11 | 1.5 |
Completeness [%] | 99.9 | 98.5 |
Redundancy | 8.1 | 8 |
CC(1/2) | 0.995 | 0.609 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.2 | 293.15 | 0.1 M SPG pH 8.2, 5.0 %w/v PEG 1500 |