Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8VEC

Deep Mutational Scanning of SARS-CoV-2 PLpro

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2023-10-14
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9537
Spacegroup nameP 21 21 2
Unit cell lengths57.958, 85.470, 82.880
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.500 - 2.000
R-factor0.1769
Rwork0.174
R-free0.21700
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle0.856
Data reduction softwareXDS (Nov 1, 2016 BUILT=20161205)
Data scaling softwareAimless (0.7.8)
Phasing softwarePHENIX ((1.20.1_4487: ???))
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.9702.050
High resolution limit [Å]2.0002.000
Rmerge0.1201.346
Rmeas0.1291.455
Rpim0.0470.543
Number of reflections283541965
<I/σ(I)>9.61.1
Completeness [%]99.695.1
Redundancy7.47
CC(1/2)0.9980.467
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.5277.150.1M trisodium citrate pH 5.5, 20% w/v PEG3000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon