8TUB
HLA B7:02 with HPNGYKSLSTL
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-07-01 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.987 |
Spacegroup name | P 1 |
Unit cell lengths | 49.211, 90.668, 104.563 |
Unit cell angles | 97.54, 93.83, 90.23 |
Refinement procedure
Resolution | 43.000 - 2.400 |
R-factor | 0.1993 |
Rwork | 0.197 |
R-free | 0.23760 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.011 |
RMSD bond angle | 1.187 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.400 | 2.490 |
High resolution limit [Å] | 2.400 | 2.400 |
Rpim | 0.130 | 0.343 |
Number of reflections | 66085 | 6521 |
<I/σ(I)> | 6.49 | |
Completeness [%] | 94.5 | 93.1 |
Redundancy | 2.8 | |
CC(1/2) | 0.953 | 0.706 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | PEG |