Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8SE8

HTRA-1 PD/SA bound to CKP 1G10

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]93
Detector technologyPIXEL
Collection date2023-02-16
DetectorDECTRIS EIGER2 X 16M
Wavelength(s)1.00
Spacegroup nameP 21 21 21
Unit cell lengths120.824, 155.362, 173.397
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.990 - 3.180
R-factor0.2602
Rwork0.259
R-free0.28230
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.001
RMSD bond angle0.438
Data reduction softwareXDS
Data scaling softwareSTARANISO
Phasing softwarePHASER
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]95.3803.297
High resolution limit [Å]3.1803.180
Rmerge0.0460.943
Rmeas0.0591.188
Rpim0.712
Number of reflections461832310
<I/σ(I)>16.21.5
Completeness [%]93.151.7
Redundancy4.74.8
CC(1/2)1.0000.569
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION729115% (w/v) PEG 3350, 4% Tacsimate pH6.0 and 0.1M Mg sulfate

227344

PDB entries from 2024-11-13

PDB statisticsPDBj update infoContact PDBjnumon