Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8PII

VHH Z70 mutant 3 in interaction with PHF6 Tau peptide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2023-06-16
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9786
Spacegroup nameP 65 2 2
Unit cell lengths135.435, 135.435, 35.425
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution44.330 - 2.350
Rwork0.200
R-free0.26320
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.390
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0415)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]44.33044.3302.430
High resolution limit [Å]2.3509.1002.350
Rmerge0.2030.0582.227
Rmeas0.2080.0602.281
Rpim0.0450.0130.490
Number of reflections8432187789
<I/σ(I)>18.8
Completeness [%]100.0
Redundancy38.729.540.2
CC(1/2)0.9990.9990.947
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52931.5M ammonium sulfate, 4.5% isopropanol, 15% glycerol

219869

PDB entries from 2024-05-15