8AW1
c-MET Y1235D mutant in complex with Tepotinib
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-02-14 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.00000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 77.833, 43.291, 89.286 |
Unit cell angles | 90.00, 90.60, 90.00 |
Refinement procedure
Resolution | 44.640 - 2.140 |
R-factor | 0.2183 |
Rwork | 0.217 |
R-free | 0.24110 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4r1v |
RMSD bond length | 0.008 |
RMSD bond angle | 0.880 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | BUSTER (2.11.8 (8-JUN-2022)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 89.280 | 2.390 |
High resolution limit [Å] | 2.140 | 2.140 |
Rmeas | 0.068 | 0.540 |
Number of reflections | 32217 | 9089 |
<I/σ(I)> | 12.91 | |
Completeness [%] | 96.6 | 97.6 |
Redundancy | 2.9 | 2.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 6.5 | 298 | PEG 8,000 |