8AU5
c-MET F1200I mutant in complex with Tepotinib
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-04-16 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1.00000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 38.484, 43.173, 88.794 |
Unit cell angles | 90.00, 91.67, 90.00 |
Refinement procedure
Resolution | 88.760 - 2.720 |
R-factor | 0.2386 |
Rwork | 0.234 |
R-free | 0.27780 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4r1v |
RMSD bond length | 0.009 |
RMSD bond angle | 1.052 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 88.760 | 2.970 |
High resolution limit [Å] | 2.720 | 2.720 |
Rmeas | 0.061 | 0.577 |
Number of reflections | 7637 | 1783 |
<I/σ(I)> | 14.16 | 2.88 |
Completeness [%] | 95.0 | 96.7 |
Redundancy | 2.9 | 2.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.6 | 293 | PEG 8000 |