Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8AU5

c-MET F1200I mutant in complex with Tepotinib

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2013-04-16
DetectorPSI PILATUS 6M
Wavelength(s)1.00000
Spacegroup nameP 1 21 1
Unit cell lengths38.484, 43.173, 88.794
Unit cell angles90.00, 91.67, 90.00
Refinement procedure
Resolution88.760 - 2.720
R-factor0.2386
Rwork0.234
R-free0.27780
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4r1v
RMSD bond length0.009
RMSD bond angle1.052
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]88.7602.970
High resolution limit [Å]2.7202.720
Rmeas0.0610.577
Number of reflections76371783
<I/σ(I)>14.162.88
Completeness [%]95.096.7
Redundancy2.92.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.6293PEG 8000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon