7ZX2
Tubulin-Pelophen B complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID30B |
Synchrotron site | ESRF |
Beamline | ID30B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-04-07 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.97625 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 104.709, 156.973, 181.043 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.660 - 2.500 |
R-factor | 0.199 |
Rwork | 0.197 |
R-free | 0.23540 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4o2b |
Data reduction software | XDS |
Data scaling software | Aimless (0.5.32) |
Phasing software | PHASER (2.7.16) |
Refinement software | PHENIX (1.19) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 49.660 | 49.660 | 2.540 |
High resolution limit [Å] | 2.500 | 13.690 | 2.500 |
Rmerge | 0.098 | 0.071 | 1.038 |
Rmeas | 0.105 | 0.077 | 1.108 |
Rpim | 0.037 | 0.030 | 0.384 |
Total number of observations | 841601 | 4842 | 42221 |
Number of reflections | 103744 | 728 | 5073 |
<I/σ(I)> | 13.5 | 34 | 2 |
Completeness [%] | 100.0 | 98.2 | 100 |
Redundancy | 8.1 | 6.7 | 8.3 |
CC(1/2) | 0.998 | 0.994 | 0.697 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | Mes, imidazole, calcium chloride, magnesium chloride, L-tyrosine, glycerol, PEG 4000 |