Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7ZFX

VDR complex with Aromatic-D-Ring Analog

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2021-07-09
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.98
Spacegroup nameP 65 2 2
Unit cell lengths65.723, 65.723, 263.897
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution24.770 - 2.600
R-factor0.2126
Rwork0.208
R-free0.25380
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2hc4
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0002.690
High resolution limit [Å]2.6002.600
Number of reflections112951017
<I/σ(I)>11.2
Completeness [%]99.5
Redundancy8.7
CC(1/2)0.9870.864
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8293NaActetae 2.5M, Tris 0.1M

221371

PDB entries from 2024-06-19

PDB statisticsPDBj update infoContact PDBjnumon