7YD3
Single-chain variable fragment of app 3D1 antibody
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL19U1 |
| Synchrotron site | SSRF |
| Beamline | BL19U1 |
| Temperature [K] | 77 |
| Detector technology | CCD |
| Collection date | 2021-10-04 |
| Detector | MAR CCD 130 mm |
| Wavelength(s) | 0.9785 |
| Spacegroup name | P 1 |
| Unit cell lengths | 47.183, 70.490, 74.815 |
| Unit cell angles | 108.83, 93.82, 90.09 |
Refinement procedure
| Resolution | 19.920 - 2.160 |
| R-factor | 0.219 |
| Rwork | 0.217 |
| R-free | 0.25370 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6kvf |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.920 | 2.240 |
| High resolution limit [Å] | 2.160 | 2.160 |
| Number of reflections | 155752 | 45947 |
| <I/σ(I)> | 7.6 | |
| Completeness [%] | 94.4 | |
| Redundancy | 3.4 | |
| CC(1/2) | 0.910 | 0.850 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 10% 2-propanol, 0.1 M HEPES pH 7.5, 20% PEG 4000 |