7SF4
M. tb EgtD in complex with imatinib
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-D |
Synchrotron site | APS |
Beamline | 21-ID-D |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2020-07-31 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.98 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 68.980, 71.131, 144.557 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.700 - 2.390 |
R-factor | 0.2237 |
Rwork | 0.221 |
R-free | 0.26360 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4uy5 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.1_4122) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.700 | 2.450 |
High resolution limit [Å] | 2.390 | 2.390 |
Number of reflections | 28869 | 690 |
<I/σ(I)> | 10 | |
Completeness [%] | 96.8 | |
Redundancy | 1 | |
CC(1/2) | 0.950 | 0.952 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298.15 | 0.2 M potassium phosphate dibasic and 20 % w/v polyethylene glycol 3,350 |