Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7SCF

M. tb EgtD in complex with HD2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-D
Synchrotron siteAPS
Beamline21-ID-D
Temperature [K]100
Detector technologyCCD
Collection date2020-07-31
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.98
Spacegroup nameP 21 21 21
Unit cell lengths69.102, 71.570, 145.095
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution50.950 - 2.670
R-factor0.2193
Rwork0.213
R-free0.28010
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uy5
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHENIX
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.9502.670
High resolution limit [Å]2.6702.670
Rmerge0.1000.450
Number of reflections210892068
<I/σ(I)>10.89
Completeness [%]99.8
Redundancy1
CC(1/2)0.9600.440
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP298.150.2 M potassium phosphate dibasic and 20 % w/v polyethylene glycol 3,350

223790

PDB entries from 2024-08-14

PDB statisticsPDBj update infoContact PDBjnumon