7S46
PAK4cat (D440N/S474E) in complex with Integrin beta5 760-770 peptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-E |
| Synchrotron site | APS |
| Beamline | 24-ID-E |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2017-03-30 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.97918 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 61.821, 61.821, 178.829 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.010 - 2.100 |
| R-factor | 0.1822 |
| Rwork | 0.180 |
| R-free | 0.21970 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4fif |
| RMSD bond length | 0.015 |
| RMSD bond angle | 1.832 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0151) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.010 | 50.000 | 2.180 |
| High resolution limit [Å] | 2.100 | 4.520 | 2.100 |
| Rmerge | 0.132 | 0.053 | 1.343 |
| Rmeas | 0.138 | 0.056 | 1.421 |
| Rpim | 0.040 | 0.017 | 0.457 |
| Number of reflections | 21249 | 2341 | 2063 |
| <I/σ(I)> | 5.1 | ||
| Completeness [%] | 99.9 | 99.7 | 100 |
| Redundancy | 11.4 | 10.5 | 9.3 |
| CC(1/2) | 0.999 | 0.447 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1 M Tris-HCl (pH 8.5) and 0.5 M tri-sodium citrate |