Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-F |
Synchrotron site | APS |
Beamline | 21-ID-F |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2019-04-18 |
Detector | RAYONIX MX-300 |
Wavelength(s) | 0.97872 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 192.300, 50.880, 49.920 |
Unit cell angles | 90.00, 93.15, 90.00 |
Refinement procedure
Resolution | 35.260 - 2.100 |
R-factor | 0.2084 |
Rwork | 0.206 |
R-free | 0.23830 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3psg |
RMSD bond length | 0.006 |
RMSD bond angle | 0.800 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MR-Rosetta |
Refinement software | PHENIX (1.19 dev 4329) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.150 |
High resolution limit [Å] | 2.100 | 9.390 | 2.100 |
Rmerge | 0.046 | 0.020 | 1.204 |
Rmeas | 0.053 | 0.024 | 1.410 |
Number of reflections | 28381 | 341 | 2079 |
<I/σ(I)> | 15.4 | 52.06 | 1.11 |
Completeness [%] | 99.8 | 96.6 | 99.6 |
Redundancy | 3.95 | 3.443 | 3.589 |
CC(1/2) | 0.999 | 0.998 | 0.654 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 9.4 | 290 | RigakuReagents JCSG A7 optimization screen: 100mM Tris HCl / NaOH pH 9.4, 17.86% PEG 8000: PlfaA.17789.b.HE11.PD38363 at 11.4mg/ml: cryo: 20% EG: tray: 3908603 D3: puck qpu2-2 |